TCH.1C-27J-2-29JG
2-28
FIRE SHUT-OFF VALVES - REMOVAL AND
INSTALLATION
INPUT CONDITION:
Aircraft Applicability:
04162, 04180
Required Conditions:
1.Disconnect external electrical power (refer to manual
2.Position maintenance platform (AGE NO. 00074).
3.Open the access panels 414J, 414D and 414F (424J
and 424D).
4.Open the access panels 913A and 913B.
Recomended Personnel:
PROCEDURE
MECH.
CODE
QTY
TOTAL TIME
(MIN.)
WORK
ZONE
Input Condition
AFM
2
25,00
Removal
AFM
2
20,00
Installation
AFM
2
20,00
Test
AFM
2
60,00
Follow
Maintenance
AFM
2
25,00
Periodicity: AR - AS REQUIRED
Total Maintenance Time: 300 (Min.)
Total Time Detention System: 150 (Min.)
AGE Required:
AGE
No.
NOMENCLATURE
P/N
00054 Kit, torque wrenches
G0001200001-001**
00074 Kit, aircraft assy platform
G0005100001
29-10-40