TCH.1C-27J-2-29JG
2-28.1 REMOVAL (refer to figure
) , (refer
to figure
) and (refer to figure
WARNING
––––––––––––––––––––––––––––––––––
HYDRAULIC FLUID IS ACID. AVOID
CONCTACT WITH SKIN AND WEAR
APPROPRIATE, IMPERVIOUS CLOTHING
WHEN HANDLING THE HYDRAULIC
FLUIDS. IF YOU DO NOT OBEY THESE
SAFETY PRECAUTIONS, SEVERE
INJURY MAY OCCUR.
––––––––––––––––––––––––––––––––––
CAUTION
––––––––––––––––––––––––––––––––––
Do not use drained fluid from Hydraulic
System. A hydraulic fluid leak may occur.
This would cause damage to the
equipment and loss of mission
effectiveness.
––––––––––––––––––––––––––––––––––
1.Connect hydraulic test stand (AGE NO. 00262) to
No.1 (No.2) system pressure and suction ground test
sockets (ground service panel).
2.Using the hydraulic test stand (AGE NO. 00262),
discharge the hydraulic reservoir system No.1 (No.2).
3.Annul pressure in both hydraulic system.
4.Verify that the reservoir is empty trough the visual fluid
level indicator.
5.Use a container to collect drained fluid (about 1 liter).
6.Loose the return union (1), cut the lock wire (2), open
the reservoir drain cock (3) and discharge the
remaining hydraulic fluid.
(Cont'd)
29-10-40