TCH.1C-27J-2-29JG
) (Cont'd)
CAUTION
––––––––––––––––––––––––––––––––––
Do not use drained fluid from Hydraulic
System. A hydraulic fluid leak may occur.
This would cause damage to the
equipment and loss of mission
effectiveness.
––––––––––––––––––––––––––––––––––
NOTE
Seal all open pipes and components holes
to prevent entrance of unwanted dust.
1.Use a container to collect drained fluid.
CAUTION
––––––––––––––––––––––––––––––––––
Install protection caps on the
disconnected electrical connectors and
hoses.
––––––––––––––––––––––––––––––––––
2.Disconnect electrical connector (26DEA (27DEA)) (5)
from low pressure switch (6) after cutting the lock
wire.
3.Remove clamp (9) by removing bolt (7), washer (8)
and nut (3) from support (4).
4.Remove the low pressure switch (6) from tee pipe (1)
by loosen nut (2).
2-30.2 INSTALLATION (refer to figure
)
and (refer to figure
NOTE
Remove protection caps from the electrical
connectors and hoses to be installed.
1.Install the low pressure switch (6) on tee pipe (1) by
screw nut (2).
(Cont'd)
29-10-50