TCH.1C-27J-2-29JG
Consumable Material Required:
None
Safety Conditions:
Be aware of information contained in SAFETY
PRECAUTIONS (refer to para
maintenance.
PROCEDURE:
)
1.Position the stepladder (AGE NO. 00076) in the
working area.
WARNING
––––––––––––––––––––––––––––––––––
REMEMBER THE EXACT SEQUENCE OF
THE CABLES TIGHTENED ON
CONTACTOR TERMINALS.
––––––––––––––––––––––––––––––––––
2.Remove the Velcro cover.
CAUTION
––––––––––––––––––––––––––––––––––
Install protection caps on the
disconnected electrical connectors.
––––––––––––––––––––––––––––––––––
3.Disconnect connector (15 DEA) (16) from pump
contactor (15 DE) (15).
4.Disconnect connector (16 DEA) (7) from pump
contactor (16 DE) (14).
5.Disconnect nuts (1 and 9) of the inlet cables (2 and 8)
and disconnect it.
6.Disconnect nuts (5 and 12) of the outlet cables (6 and
13) and disconnect it.
7.Loosen the screws (3) and washers (4) from pump
contactor (15 DE) (15).
(Cont'd)
29-10-60
2-222