TCH.1C-27J-2-29JG
2-3.3
TUBING REPAIR PROCEDURES (refer to figure
(b)Use a tube splice and two compatible
PERMASWAGE union fittings to recreate the
section of tubing which was removed.
Assemble these parts into the line being
repaired before you swage the fittings.
(c)Swage each end of fittings.
C.TYPE 3: leaking elbow, tee, or cross.
(a)Cut out defective elbow, tee, or cross. Make
cuts only after checking to make sure enough
space in which to operate swage tool.
D.Swage tube splices to a compatible
PERMASWAGE elbow, tee, or cross fitting. Do this
to re-create section of tubing system which was
removed.
(a)Swage each leg (tube) of this assembly to the
tubing being repaired. Use PERMASWAGE
union fittings.
FOLLOW ON MAINTENANCE:
None
29-00-20
2-13